2. If the card number appearing in the FAULT
5. Momentarily press front panel DISPLAY RESET
LOCATION display is 15 or less,  replace card as
switch.
prescribed in paragraph 6-22.  If the displayed card
number is 16 or greater, set POWER CONTROL switch
6. Upon release of DISPLAY RESET switch,
to OFF, and then replace card as pre- scribed in
observe that all error indicators remain out and POWER
CONTROL ON indicator is lighted.
3. If POWER CONTROL switch was previously set
to OFF, set switch to ON.
7. Perform a lamp test as pre- scribed in paragraph
4. Set SELF TEST switch of off (down) position.
6-13.
TROUBLESHOOTING.
5. Momentarily press DISPLAY RE-SET switch.
6-14.  GENERAL.  Although the multiplexer set has
6. Upon release of DISPLAY RESET switch,
many built-in diagnostic features, certain limited types of
observe that all front panel error indicators remain out
mal- functions must be isolated by the use of
and POWER CONTROL ON indicator is lighted.
conventional troubleshooting techniques. The following
paragraphs provide useful information for performance of
7. Perform a self-test as pre- scribed in paragraph
such troubleshooting.
6-15.  Table 6-2 lists a number of abnormal multiplexer
6-12.  LAMP TEST MODE. A lamp test feature is
set operating symptoms, together with their probable
provided for detection and isolation of defective front
causes. Appropriate corrective actions are also listed.
panel indicator lamps and displays. Perform detection
Table 6-3 lists, by name, the signals appearing within the
and isolation procedures as follows:
multiplexer set. The function of each signal is also listed.
Special purpose switch data useful in troubleshooting the
1. Press LAMP TEST switch and observe which
equipment are listed in table 6-4.
front panel indicator lamp or FAULT LOCATION display
is not lighted or is indicating an incorrect number.
6-16.  Many numbered test points are located at the
outer edges of the cards within the multiplexer set. Most
NOTE
maintenance-significant operating and diagnostic signals
are routed to these test points. The signals appearing at
During  lamp  test,  the  correct
these test points are listed in table 6-3. The signals
numerical indication for the FAULT
appearing at other card edge test points may be
identified by referring to the logic diagrams in the circuits
LOCATION display is 88.
diagram manual.
2. Release LAMP TEST switch and set POWER
6-17.  EXTENDER CARD USAGE.  Monitoring of a
CONTROL switch to OFF.
signal on a card that does not appear at a card edge test
point is accomplished by using the extender card
3. Replace indicator lamp or numerical display-
(extender card assembly P/N 61864080- 009), which is
element observed in step 1 as prescribed in paragraph
stored in slot 22 of the
6-25 or 6-26, respectively.