Click here to make tpub.com your Home Page

Page Title: SELF-TEST MODE
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

T.O. 31W2-2GSC24-2
TM 11-5805-688-14-1
NAVELEX 0967-LP-545-3010
NOTE
MULTIPLEXER OUT OF TOL indicator
Hazardous voltages are present at the power
may be lighted after step 14 is per-
supply electrical connectors.
Turn off
formed. When indicator is lighted, wait
operating power and disconnect power cord
approx- imately 40 seconds and repeat
before
attempting
power
supply
step 14.
replacement; otherwise, personnel death or
injury may result.
14. Upon release of DISPLAY RESET switch,
observe that all front panel error displays remain out and
4. Set POWER CONTROL switch to OFF.
POWER CON TROL ON indicator is lighted.
5. Disconnect multiplexer set power cord from its
15. Perform a self-test of the multiplexer set
source outlet.
diagnostic circuits as prescribed in paragraph 6-32.
6. Replace power supply assembly as prescribed in
6-11. SELF-TEST MODE. A manually initiated self-test
mode is provided for detection and isolation of faults
occurring in the diagnostic circuits on the multiplexer set
7. Connect multiplexer set power cord to its source
printed circuit cards. Faults detected during self-test are
outlet.
displayed by front panel error indicators. In the self-test
mode,
the
MULTIPLEXER
CARD
and
8 Set POWER CONTROL switch to ON.
DEMULTIPLEXER CARD indicators are normally lighted
and the number 00 appears in the FAULT LOCATION
9. Momentarily press DISPLAY RE-SET switch.
display.
(Refer to paragraph 6-32 for self-testing
procedures.) An abnormal display is indicative of a card
10. Upon release of DISPLAY RESET switch,
with faulty diagnostic circuits; perform corrective action
observe that all front panel error displays remain out and
as follows:
POWER CON- TROL ON indicator is lighted.
1. With SELF TEST switch in on (up) position,
11. If the card number appearing in the FAULT
observe which error indicator (MULTIPLEXER CARD or
LOCATION display is 15 or less, replace card as
DEMULTI- PLEXER CARD) is not lighted, and the card
prescribed in paragraph 6-22.  If the displayed card
number that appears in the FAULT LOCATION display.
number is 16 or greater, set POWER CONTROL switch
to OFF, and then replace card as prescribed in
NOTE
The SELF TEST switch must remain in the
12. If POWER CONTROL switch was previously set
on (up)  position  for approximately 15
to OFF, set switch to ON.
seconds before final error information is
displayed.
13. Momentarily press DISPLAY RE-SET switch.
6-4

Privacy Statement - Press Release - Copyright Information. - Contact Us