Page Title: Table 6-4. Special Purpose Switch Data
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

T.O. 31W2-2GSC24-2
TM 11-5805-688-14-1
NAVELEX 0967-LP-545-3010
Table 6-4. Special Purpose Switch Data
Location
Switch
Function
Display card
S1
Diagnostic NORM/MUX OFF/DEMUX OFF switch. In the MUX OFF
position, all multiplexer error displays are inhibited.
In  the
DEMUX OFF position, all demultiplexer error displays are
nhibited. In the NORM position, all multiplexer and demultiplexer
error display circuits are enabled.
FS card
S3A,
NORM/LOOPBACK switch. In LOOPBACK position, these
S3B
switches connect serial data and timing outputs of the
multiplexer to serial data and timing inputs of the demultiplexer.
OEG card
S1
Fifteen-section DIAGNOSTICS AND OVERHEAD switch.  Each
separate section has ON and OFF positions, and is associated
with one channel. In OFF position, a positive
stuff
request
(MPSTXX- or DPSTXX-) originating at a channel card is inhibited
at the OEG card. This precludes the display of channel card
errors, and prevents the channel card (multiplexer only) from
receiving positive stuff overhead service.
RCB card
S6
DIAG ON/OFF switch.  In OFF position, switch inhibits normally
generated card error signals from leaving the RCB card. The
error signal generated during self-test is not inhibited in either the
OFF or ON switch position.
RCB card
S7
OOT out-of-tolerance ON/OFF switch.  In OFF position, switch
inhibits an out-of-tolerance signal from leaving the RCB card.
RT card
S3
Phase adjustment switch. Adjusts phasing of TIMOUT and TIMOUT-
signals generated by RT card. Switch is set to position most
nearly provided coincidence between transitions of TIMOUT and
TIMOUT- signals.
SB card
S4
DIAG ON/OFF switch.  Function of this switch is same as that
described for S6 on the RCB card.
TD card
S1
DIAG ON/OFF switch. Function is same as that described for S6 on
the RCB card.
TE/TR card
S8
NORM/DIAG OFF switch. Function is same as that described for S6
on the RCB card.
6-18