T.O. 31W2-2GSC24-2
TM 11-5805-688-14-1
NAVELEX 0967-LP-545-3010
Table 6-2. Troubleshooting Symptoms (Cont)
SYMPTOM
PROBABLE CAUSE
CORRECTIVE ACTION
Miscellaneous Indications (Cont)
LOSS OF FRAME A indi-
a. Demultiplexer input
Correct signal source.
cator lighted;
data signal missing.
equipment previously
operating normally.
b. Defective frame sync card.
Replace card.
LOSS OF FRAME A indicator Demultiplexer port strap-
Correct port strapping
lighted immediately
ping not same as trans-
error.
following equipment
mitting multiplexer
reconfiguration.
port strapping.
Table 6-3. Signal Name and Test Point List
1
Signal Name
Function
Test Point
NOTE
To locate a signal name prefixed by M (multiplexer) or D (demultiplexer),
delete the prefix and locate the remainder of the signal name. For example,
signal MNSE- is listed as NSE-, etc.
ACFANH
Fan ac (hot)
ACFANN
Fan ac (neutral)
ACINH
AC input (hot)
ACINN
AC input (neutral)
ACPSH
Power supply ac (hot)
ACPSN
Power supply ac (neutral)
ATA
Demux input data
ATA-
Demux input data
CHAD 1
Channel address 1 (binary 1)
M/D21-10
CHAD 2
Channel address 2 (binary 2)
M/D21-11
CHAD 4
Channel address 4 (binary 4)
M/D21-12
CHAD 8
Channel address 8 (binary 8)
M/D21-13
See footnote at end of table.
6-9
|