(2) Remove and retain the ten screws securing the panel to the chassis.
(3) Gently pull the panel forward to the extent of the service loop in the
wiring harness.
(4) Lower and support the panel.
(5) Remove the threaded bushing from the circuit breaker actuator shaft.
Retain the bushing for reassembly.
b. Label and unsolder all wires connected to the defective assembly.
c. Remove and retain the four countersunk screws securing the assembly to the
front panel.
d.
Remove and retain the nuts and washers from the two remaining screws
securing the assembly to the panel. Remove and retain the screws.
e. The assembly may now be removed from the panel.
Install a replacement assembly as follows:
5-4.12.2 Installation.
Remove and retain the four pan-head screws from the front of the replace-
a.
ment assembly.
b. Position the assembly on the front panel and secure using the hardware
retained in steps c. and d.
c. Solder the connecting wire to the terminals of the assembly.
d. Raise and secure the front panel. Refer to para 5-4.12.1.a.
e. Ensure the assembly is fitted with serviceable lamps. Refer to para 5-9.
f. Install the four pan-head screws retained in step a. in the defective
assembly. Repair as described in para 5-9.
unit carry out the following steps:
a. Remove top and bottom covers. Refer to para 5-4.1.
b. Label and unsolder the connections to the assembly.
c. Remove and retain the jam-nut securing the assembly to the front panel.
d. Remove and retain the cover and spring washer.
e. Remove the assembly from the panel.
NOTE
Use insulated sleeving (heat-shrink) of the appropriate inside
diameter on soldered connections.