TM 32-5865-069-24&P
f. To install a replacement assembly, reverse the procedure detailed in
steps a. thru e. above.
To remove/replace B1 carry out
the following steps:
a. Remove top and bottom covers. Refer to para 5-4.1,
b. Label and remove the three wires connected to the terminal block on B1.
Remove and retain the hardware securing the two cable clamps supporting the
c.
wire harness on B1.
Remove and retain the four screws, lock washers, and flat washers securing
d.
B1 to the mounting plate.
e. Carefully remove B1 from the unit.
f.
To install a replacement, reverse the procedure detailed in steps a. thru e.
To remove/replace Cl carry out the
following steps:
a. Remove the top cover. Refer to para 5-4.1.
b.
Label and disconnect the three wires connected to the terminals of B1.
c.
Remove and retain the two screws and washers securing C1 mounting bracket
to the rear of the chassis.
d.
Unsolder the leads of the capacitor from terminals E3 and E4.
e.
Remove the faulty capacitor from the spring clip.
f. To install a replacement, reverse the procedure detailed in steps a. thru e.
replace a circuit breaker carry out the following steps:
a. Remove the top cover. Refer to para 5-4.1.
b.
Lower the front panel as follows:
CAUTION
An RFI gasket is fitted to the front panel. Ensure the gasket is
undamaged and seats properly when the panel is replaced.
(1) Unscrew the rubber boot on the POWER RESET actuator. The boot should
be finger-tight.
5-31
Change 2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |