TM 32-5865-069-24&P
(3) Disconnect the coaxial connector at the E1 end of the cable.
(4) Remove the cable from the unit.
(5) To install a replacement cable, reverse the procedure detailed in
steps d.(1) thru d.(4). Torque the SMA connector to 8 inch-pounds.
(6) Replace top and bottom covers, refer to para 5-4.1.
e. Remove cable assemblies W18 thru W20 as follows:
(1) Remove A14, refer to para 5-4.2 for procedure. Store A14 safely.
(2) Disconnect the connector at the J1 end of the cable. Refer to
CAUTION
When unfastening cable-ties, take care not to cut or damage the
wiring in the wiring harness.
(3) Unfasten the cable ties securing the cable to the wire harness.
(4) Using extraction tool CET-C6B, remove the coaxial contact from XA14P2
at the El end of the cable. Refer to table 5-5.
(5) Remove the cable from the unit.
(6) To install a replacement cable, reverse the procedure detai led in
steps e.(1) thru e.(5). Torque SMA connectors to 8 inch-pounds.
(7) Replace top and bottom covers. Refer to para 5-4.1.
on the front panel. Replace a faulty assembly as described in the following
subparagraphs.
NOTE
Individual indicator lights can be replaced without removing the
assembly from the unit. Refer to para 5-9.
To remove a defective assembly from the unit carry out the
5-4.12.1 Removal.
following steps:
a. Lower the front panel as follows:
CAUTION
An RFI gasket is fitted to the panel. Ensure the gasket is undamaged
-
and seats properly when the panel is replaced.
(1) Unscrew the rubber boot on the POWER RESET actuator. The boot should
be finger-tight.
5-29
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |