TM 3-1040-276-23
Section IV. TROUBLESHOOTING PROCEDURES
actions. If a malfunction is not listed or is not corrected
2-5. ORGANIZATIONAL MAINTENANCE TROUBLE-
by listed corrective actions, notify your supervisor.
SHOOTING PROCEDURES.
a. The table (p 2-8) lists the common malfunctions
c. Before you use the troubleshooting table, check
with the operator to determine if all operator trou-
that may be reported to you by the operator or you may
bleshooting procedures for the reported malfunction
find during maintenance of the M3A4 smoke generator
have been followed. If in doubt, repeat the operator
or its components. Perform the tests/inspections and
troubleshooting procedures before proceeding and
corrective actions in the order listed.
after replacing faulty components.
b. This manual cannot list all malfunctions that may
occur, nor all tests or inspections and corrective
SYMPTOM INDEX
Troubleshooting
Procedure
Page
AIR PRESSURE GAGE
Registers low pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
AIR PUMP ASSEMBLY/AIR ACCUMULATOR ASSEMBLY
Gives weak or no starting air blast . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
FOG OIL EXHAUST HOSE
Gushes fog oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-10
FOG OIL PUMP
Fails to pump fog oil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-11
IGNITION CABLE/MAGNETO
Gives no spark or weak spark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-9
MAGNETO AIR PUMP ASSEMBLY
Fails to purge smoke/exhaust gases from engine . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-12
TROUBLESHOOTING
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. AIR PRESSURE GAGE REGISTERS LOW PRESSURE.
Step 1. Check air accumulator and air pump assembly for loose fittings and connections and for
cracks in air pump assembly and air accumulator.
Tighten loose fittings and connections and replace cracked air pump assembly (p 2-32)
and air accumulator (p 2-15).
Step 2. Check air accumulator check valve.
Replace faulty air accumulator check valve (p 2-19).
2-8
|