TM 3-1040-276-23
TROUBLESHOOTING (CONT)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 3. Check air pump assembly check valve and filter plug.
Replace faulty check valve and filter plug (p 2-31).
Step 4. Check air pressure gage.
Replace faulty air pressure gage (p 2-20).
2. AIR PUMP ASSEMBLY/AIR ACCUMULATOR ASSEMBLY GIVES WEAK OR NO STARTING AIR BLAST.
Step 1. Air hose split, cut, or doesn't fit.
Replace air hose (p 2-42).
Step 2. Control valve stuck.
Replace control valve (p 2-20).
3. IGNITION CABLE/MAGNETO GIVES NO SPARK OR WEAK SPARK.
CAUTION
Handle ignition cable with care. Rough handling cracks insulator. When you pump magneto air pump
handle, stop short in both directions. Use short strokes about 8 inches long. Rough handling cracks
magneto air pump clamp.
Step 1. Ignition cable contacts (1) corroded or insulator (2) cracked.
Clean cable contacts. Repair damaged cable (p 2-71).
Change 1
2-9
|