After-Charging Procedure.
WARNING
(1) Close the high-pressure sphere valve.
See that the locking collar on the
(2) Close the filling line valves (3). Observe
quick-disconnect  coupling  half  is
the pressure indicated on each gage (1). With chalk,
fully retracted and resting against the
mark the pressure on each cylinder.
first wrenching surface. Do not push
(3) Close the valves on the cylinder.
locking collar forward since this will
(4) Open the filling line valves.
release the coupling half from the
(5) Bleed all rubber hoses.  Disconnect the
charging fitting.
bleeder valve assemblies from the check valves.
c.  Screw the safety plug (3, fig. 13) into the end of
Replace the threaded caps on the check valves (7);
the charging hose assembly.
Attach the quick-
wrenchtighten the caps.
disconnect coupling half (2) that is on the other end of
(6) Disconnect the filling lines from the
the charging hose to the plug on the high-pressure
cylinder adapters (19, fig. 2).  Use two wrenches and
sphere valve (2, fig. 10).
take care not to twist or kink the metal hose (4, fig. 8).
d. Open the high-pressure sphere valve.
Support the lines during the operation so that their full
e. Read the gage (1, fig. 13) on the charging hose
weight does not hang on the metal hose.
to determine the pressure in the pressure tank.
(7) Remove cylinder adapters from cylinders.
f.  Close the high-pressure sphere valve and
(8) Replace the safety plug assembly (25, fig.
remove the charging hose assembly.
(9) Replace  the  commercial  air  cylinder
WARNING
protection cap.
See that the locking collar on the
13.
Testing Pressure in a High-Pressure
quick-disconnect  coupling  half  is
Sphere
fully retracted and resting against the
a. Verify that the high-pressure sphere valve is
first wrenching surface. Do not push
closed.
locking collar forward since this will
b. Disconnect the pressure hose from the plug on
release the coupling half from the
the high-pressure sphere.
charging fitting.
g. Connect the pressure hose to the plug on the
high-pressure sphere valve.
1
Gage2
Quick-disconnect coupling half
3  Safety plug
Figure 13. Charging hose assembly ready to teat the pressure of ABC-M9-7 or
M9A1-7 flamethrower high-pressure sphere.