Pressure hose
2
High-pressure sphere valve
3 High-pressure sphere
Figure 10. M9 tank group.
(5) During charging, check the pressure gage to
NOTE
make sure that the pressure is increasing at a uniform
There are four models of the AN-M4
rate.
Refer to applicable
(6) When the high-pressure sphere has been
technical manual (appendix) for the
charged to a pressure of 2,000 psi, close the high-
type of compressor being used.
pressure sphere valve.
WARNING
(8) Stop the engine.
Open globe valve with caution. The
d. After-Charging Procedure.
oil, water, and air emulsion released
(1) Open the bleeder valve (6, fig. 8) on the 6-foot
under pressure can cause injury to
rubber hose one-fourth turn.
personnel.
(2) Remove the charging line from the plug on the
(7) Open the globe valve (6, fig. 6) one- half turn.
high-pressure sphere valve (2, fig.
16