Click here to make tpub.com your Home Page

Page Title: FUEL TANK
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 10-7360-204-13&P
Replacement
c.
(1) Replace air gage by turning clockwise until tight.
(2) Pressurize the system (para 2-6) and check for leaks.
NOTE
A soap and water solution can be applied to fuel system fittings to check for leaks.
(3) Replace the top shield (para 4-9.1).
4-9.6 FUEL TANK
Preliminary Requirements.
a.
(1) Remove top shield (para 4-9.1).
(2) Remove generator (para 4-9.2).
(3) Remove spare generator (para 4-9.2).
(4) Remove burner, bottom shield, mixing chamber and air shutter assembly (para 4-9.3).
(5) Remove preheater assembly (para 4-9.4).
(6) Remove pressure gage (para 4-9.5).
(7) Remove safety valve device (para 4-9.10).
Do not drain fuel while smoking or near an open flame or injury may result.
(8) Drain fuel tank by removing drain plug and standing tank with drain down and slightly tipped to allow fuel to
drain out of tank. Drain into an approved container. During draining of fuel, remove filler cap on U-Tank.