TB 9-2350-257-20-1
STEP 3
Place MASTER BATTERY switch to ON Place FUEL
PUMP switch to ON Measure voltage 22 to 26 VDC on
"T" harness socket A (+) to socket C (-) (Circuit 1A).
a. If 22 to 26 VDC exists, proceed to step 10
b. If 22 to 26 VDC does not exist, proceed to step 4
STEP 4
Place MASTER BATTERY switch to the OFF position
Disconnect harness 11673835 from the driver's master
control panel.
Check continuity from harness connector 11673835 pin
C (Circuit 1 A) to socket A on the "T" harness.
a. If continuity does not exist, repair harness
11673835.
b. If continuity exists, proceed to step 5.
9
|