Table 4-2. Unit Troubleshooting - Continued
ITEM
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5.
ENGINE OPERATES WITH OIL PRESSURE BELOW 15 PSI
CAUTION
Troubleshoot engine for low oil pressure along with the steps below. Failure
to correct this problem can lead to serious engine damage.
Step 1. Test wiring harness (para 4-25).
Replace or repair harness (para 4-25).
Step 2. Replace oil pressure switch.
Step 3. Test oil pressure gauge (para 4-26).
Replace oil pressure gauge (para 4-26).
6.
WINTERIZATION HEATER DOES NOT OPERATE
Step 1. Inspect wiring harness for damage and test (para 4-42).
Repair or replace harness (para 4-42).
Step 2. Test fuel pump (para 4-41).
Replace fuel pump (para 4-41).
Step 3. Test control box (para 4-40).
Replace control box (para 4-40).
Step 4. Replace heater (para 4-39).
7.
COMPRESSOR FAILS TO BUILD UP OR MAINTAIN REQUIRED PRESSURE.
Step 1. Check drive belts for damage or slipping.
Adjust or replace drive belts (para 4-22).
Step 2. Check compressor pilot valve for proper adjustment.
Adjust pilot valve (para 4-27).