TM 32-5865-069-24&P
(6) Use the four screws retained in step b.(2) to secure the printed
wiring board to the assembly.
(7) Solder the printed wiring board to the assembly.
(8) Ensure the repaired assembly meets all the requirements of table 5-9.
to para 5-2. The assembly is repaired by replacing faulty or damaged components
and cables. RF cable routing is described in table 5-10. Table 5-11 is a wire
list for the assembly. The following subparagraphs provide general instructions
for the replacement of components:
CAUTION
When disconnecting or reconnecting miniature coaxial cables, take
care not to twist or strain the cable.
NOTE
Before replacing a suspected defective component, ensure the asso-
ciated wiring is not defective.
Use the wire list, table 5-11, and
schematic diagram FO-18.
a. Replace top plate mounted components (S1, AR1) as follows:
(1) Disconnect coaxial cable connection(s) to the defective component.
(2) Label and unsolder all connecting wires at the terminals of the
defective component.
(3) Remove and retain the three screws and washers securing the top-plate
to the threaded posts.
(4) Carefully separate the plates to allow access to the mounting
hardware.
Converter, IF (A20), Cable Routing
Part
Reference
Number
P1
P2
designation
5053047-7
AT1-J1
S1-J5
W1
6053048-11
AR1-OUT
FL1-A
W3
5053048-6
FL1-B
U1-RF
W4
5053047-8
Y1-J1
U1-LO
W5
AR1-IN
5053239-7
AT1-J2
W2
|