TM 32-5865-069-24&P
Converter, IF (A20), Wire List
To
From
Wire no.
S1 GND
J1-1
1
AR1 GND
S1 GND
2
G1-3
3
AR1 GND
4
AT1 GND
G1 GND
S1 +5V
5
J1-2
E4
S1 +5V
6
E4
AT1 +5V
7
AR1 +15V
8
J1-3
Y1-1
9
J1-4
S1-1
J1-5
10
S1-2
J1-6
11
S1-3
J1-7
12
S1-4
J1-8
13
AT1-1
J1-9
14
AT1-2
J1-10
15
Not Connected
J1-11
16
17
AT1-4
J1-12
E3
AT1-3
18
(5)
Remove and retain the hardware securing the defective component to
the plate.
Position the replacement component on the plate and secure using the
(6)
hardware retained in step a.(5).
(7)
Secure the top-plate to the threaded spacers.
NOTE
insulated sleeving (0.125 ID HTSK CLR) on all wires connected to
S1.
(8) Solder the wires removed in step a.(2) to the terminals of the
..
replacement component.
(9) Reconnect to coaxial cable(s). Torque the connectors to
8 inch-pounds.
(10) Test the assembly using AN/USM-410 to verify repair.
|