b. Attaching Filling Line Assembly (27, fig. 2) to
cylinder valve and open the bleeder valve.
d. After Charging Procedure for Commercial Air
Commercial Air Cylinder.  Follow directions given in
Cylinder. Follow directions given in paragraph 16d.
e. Charging Two
or More Commercial Air
c. Charging.
Cylinders Simultaneously.
(1) Start the compressor engine (TM 3-1040-
Charge  two  or  more
203-12).
commercial air cylinders simultaneously (a through d
(2) Open the cylinder valve (2, fig. 9).
above) and perform the following:
(3) Close the charging manifold bleeder valve
(1) Attach cylinders in series with filling line
(1, fig. 12) that is on the side of the manifold where the
assemblies.
charging line is attached.
(2) Before filling, open, all cylinder valves (2,
(4) Observe the discharge pressure gage (2,
fig. 9) and filling line valves (1).
fig. 11) on the manifold and the pressure gage (20, fig 2)
(3) Charge commercial air cylinders (c and d
of the filling line assembly.
above).
When either gage shows 2,000 psi, close the
Section V. TESTING AND ADJUSTING PRESSURE REGULATOR ON
PORTABLE FLAMETHROWER I OR RIOT CONTROL AGENT DISPERSER
sockethead screw keys (para 3n(7)) to test and adjust
18.
M2A1-7 Flamethrower
the pressure regulator on the M3 riot control agent
disperser (TM 3-1040-214-12).
Use the M2A1-7 portable flamethrower fuel tank test
gage assembly and the 5/32-inch sockethead screw
20.
ABC-M9-7 or M9A1-7 Flamethrower
keys (para 3n(7)) to test and adjust the pressure
regulators on the M2A1-7 portable flamethrower (TM 3-
Use the ABC-M9-7 flamethrower fuel tank test gage
1040-204-14).
assembly to test the pressure regulator on the ABC-M9-7
19.
M3 Riot Control Agent Disperser
or M9A1-7 portable flame-thrower (TM 3-1040-211-30
or TM 3-1040-257-12).
Use the agent tank test gage assembly and the
Section VI. USING KIT FOR FUEL FILLING
WARNINGS
earth at flame-fuel filling site for use
Do not smoke within 50 feet of a
on gasoline or flame-fuel fires.  DO
flame-fuel filling operation.
NOT  USE  WATER  ON  BURNING
FLAME FUEL OR GASOLINE.
To prevent any irritation, all parts of
the body that come in contact with
When applying pressure to a fuel
gasoline or a flame fuel must be
drum,  always  use  the  pressure
washed with soap and water.
regulator  sup-plied  with  the  kit.
Using a different pressure regulator
Never move a flame-fuel drum while
may cause the flame-fuel drum to
pressure is being applied.
explode.
Use ONLY flame fuel per TM 3366
Do not permit open flames, heated
when filling flamethrowers or flame
stoves, or the operation of electrical
landmines for flame operations.
apparatus or equipment that cause
sparks within 50 feet of fuel-filling
Never
use
gasoline
to
fill
operations.
Never store gasoline
flamethrowers or flame landmines.
tanks or flame-fuel tanks near heat.
Do  not  kink  flame-fuel  hose  or
Remove spilled flame fuel or gasoline
gasoline hose.  Do not let hoses
immediately.
contact hot surfaces.
Use only appliances approved for use
Keep carbon-dioxide or dry-type fire
in atmospheres containing flammable
ex-
vapors.
tinguishers or containers of sand or
24