cylinders must have a minimum pressure of 600 psi.
WARNING
One or more of the cylinders must have a pressure of at
Open glove valve with caution. The
least 1,800 psi. If available, at least two cylinders, and
oil, water, and air emulsion released
preferably four or more, should be used together to
under pressure can cause Injury to
acquire maximum pressure.
personnel.
b. Charging Capacity. Full commercial air cylinders
can charge the approximate number of pressure tanks
(5) When the pressure tank has been charged to a
listed below:
pressure of 2,000 psi, open the globe valve one-half turn
No of full
No (approx ) of
to permit the high- pressure air to escape and blow down
commercial
pressure tanks that
the oil, water, and other material accumulated in the
are cylinders
can be charged
separator.
1 -------------------------------------------2
(6) Stop the engine.
2 -------------------------------------------6
d. After-Charging Procedure.
4 -------------------------------------------24
(1) Open the bleeder valve (10) one- fourth turn.
5 -------------------------------------------36
(2) Disconnect the rubber-hose valve assembly (34,
6 -------------------------------------------48
fig. 2) from the pressure tank check valve (9, fig 6)
Replace and tighten the check valve cap (8)
c. Apparatus.  Use two 6-foot rubber hose as-
6. Using M1A1 Compressor
semblies (36, fig. 2) and a filling line assembly (27) to
Connect the 6-foot rubber hose assembly (2, fig.
charge two M2A1-7 flamethrower pressure tanks from
7) between the M2A1-7 flamethrower (1) and the
two commercial air cylinders.
charging line adapter on the MIA1 compressor. Charge
Use one 6-foot rubber hose assembly (36) and cap the
the pressure tank (TM 3-1040- 203-12).
unused safety plug assembly (25).
7. Using Commercial Air Cylinder
d. Attaching  Filling  Lines  to  Commercial  Air
a. Volume and Pressure Full commercial air
Cylinders. Charge two M2A1-7 flamethrower pressure
cylinders contain 200 to 220 cubic feet of air. All
tanks from two commercial air cylinders (fig. 8) as
follows:
(1) Remove the protection caps from the valves of
the cylinders.
(2) Immediately before coupling a fitting
1 M2A1-7 flamethrower
2 Hose assembly
Figure 7. Charging M2A1-7 flamethrower with M1A1 compressor.