REPLACEMENT OF PARTS
a. This section gives the necessary procedures to repair and replace damaged parts
on Radiac Sets AN/PDR-27(#).
b. The
column gives the area of the damaged item.
c. The
column tells what item must be replaced.
d. The
column describes the steps to be followed in order to replace and repair
the damaged item.
TABLE 2-4. REPLACEMENT OF PARTS
Action
Task
Item No.
Location
1) Completely loosen the 3 captive
Replace rubber
Battery
1
screws
gasket
Compart-
2) Remove the battery compartment
(diagram 1)
ment
cover.
3) Inspect the rubber gasket for dam-
age, (tears, frays, excessive wear and
looseness). If the rubber gasket is dam-
aged, then remove the gasket.
4) Secure a new rubber gasket in place with
cement. Make sure that the gasket is
seated properly in the recessed groove
and remove any excess cement from
around the edges.
5) Let the cement dry for 5-10 minutes, then
replace the battery compartment cover.
6) Tighten the 3 captive screws.
Tighten the screws securely in
order to maintain a watertight
battery compartment. Do not
tighten too tightly or damage
may result to the rubber
gaskets.