CHAPTER 3
OPERATING INSTRUCTIONS
Control, Indicator, or jack
Function
POWER (2-position toggle) switch
Controls primary power to TS-2669/GCM.
POWER ON indicator
Lights to indicate ac power is on.
1 AMP fuse
Protects ac input line.
RECEIVE LEVEL DBM (7-position rotary) switch
Attenuates input signal fed to input amplifier. Indi-
cated number corresponds to level in dbm. Minimum
attenuation is at setting of -40.
TRANSMIT LEVEL DBM (4-position rotary) switch
Controls output signal level. Indicated number corre-
sponds to power level in dbm. Maximum output level
is at setting of +10.
TRANSMIT LEVEL DBM control
Provides fine adjust for output signal level. Between
0 and 10 db can be added to level set by 4-position
TRANSMIT LEVEL DBM switch.
BAL RECEIVE jack
Accepts telephone-type plug for application of balanced
input signal, terminated in impedance between 130
and 900 ohms.
75 Ω UNBAL RECEIVE jack
Accepts BNC connector for application of unbalanced
input signal, terminated in impedance of 75 ohms.
(5-position rotary) switch
Selects terminating impedance for input signal. With
RECEIVER IMPEDANCE
75 (ohms) setting, 75 Ω UNBAL RECEIVE jack
must be used. With other 4 settings, 130 to 900
(ohms), BAL RECEIVE jack must be used.
MODULATION FREQUENCY HZ (3-position rotary)
Selects modulating frequency in Hz. Note that 83 1/3
switch
number is in red; this means that when switch is in
this position, red numbers on instrument are to be
used, instead of black numbers. Black numbers are
used with modulating frequencies of 25 or 250 Hz.
MOD FREQ ADJ control
Adjustable control for varying modulating frequency in
end-to-end mode of operation. Frequency can be
changed up to 50 parts per million (PM).
% MOD ADJ control
Adjust control for varying percentage of modulation
between 0 and 50 percent. This should always be set
for a nominal 50 percent modulation.
dbm/% MODULATION meter
Measures percentage of modulation or signal level in
dbm, as selected by % MOD/RECEIVE LEVEL/
TRANSMIT LEVEL switch. To determine correct
signal level, meter indication must be added algebrai-
cally to RECEIVE LEVEL DBM or TRANSMIT
LEVEL DBM switch setting number. If meter reads
-6, and RECEIVE LEVEL DBM or TRANSMIT
LEVEL DBM switch is set to -10, correct level is -16
dbm. If either switch was set to +10, then correct level
would be +4 dbm. TRANSMIT LEVEL DBM and
RECEIVE LEVEL DBM switches should be set so
that dbm/% MODULATION meter reading is always
between 0 and -10 dbm.
% MOD-RECEIVE LEVEL-TRANSMIT LEVEL (3-
Selects which parameter dbm/% MODULATION
position rotary) switch
meter will measure.
3-1
|