ELECTRICAL
SERVICE
CARD NO.
MAN
WORK
WORK UNIT
7 Day Inspection
INSPECTION
POWER
ON
IN
1-003
MIN
AREA
SYSTEM
SUB-SYS
REQUIREMENTS
(Cont'd from card 1-002)
D.
Restore power to rectifier 1PS1 by placing AC INPUT circuit breaker in
ON position RFA lamp on the Meter and Control Panel should not be off.
0015
E.
Remove power from rectifier 1PS2 by placing AC INPUT circuit breaker in
the OFF position. RFA lamp on the Meter and Control Panel should now be lit, and both
meters on this panel should still indicate the values observed in step B. On rectifiers 1PS1
and 1PS3 the ammeters should each indicate approximately half the current indicated on
the Meter and Control Panel ammeter and the voltmeter indication should remain
unchanged.
F.
Restore power to rectifier 1PS2 by placing AC INPUT circuit breaker in
ON position. RFA lamp on the Meter and Control Panel should now be off.
CARD NO.
WORK AREAS
TYPE MECH RQR
MECH NO.
CARD TIME
PUBLICATION
T.O. 31W2-4-203-6WC-1
NUMBER
T.M. 11-6130-363-14-1/2
1-003
0055