TM 11-5895-1123-34
Section II. TROUBLESHOOTING
4-4. General
b. Table 4-7 contains the minimum performance
This section contains test and adjustment procedures,
standards to be used in testing, adjusting, and
minimum performance standards, and troubleshooting
troubleshooting the 20-Hz ringing supply assembly.
guides for the modules of the -48 vdc power supply, the
Refer to figure FO6 for a schematic diagram, and figure
20 Hz ringing supply assembly, and the control monitor -
4-8 for test setup.
48V/20 Hz assembly.
c. Table 4-8 contains the minimum performance
4-5. Performance Test and Schematic Diagram
standards to be used in testing and troubleshooting the
Locations
control monitor 48V/20 Hz assembly. Refer to figure FO-
a. Table 46 contains the minimum performance
7 for a schematic diagram and figure 4-10 for test setup.
standards to be used in testing, adjusting, and
d. Removal and replacement procedures for the
troubleshooting the -48 vdc power supply. Refer to
individual modules or components are covered in
figure FO-5 for a schematic diagram, and figure 4-7 for
Section III of this chapter.
test setup.
Figure 4- 7. Test Setup for -48 Vdc Power Supply.
Table 4-6. Performance and Troubleshooting Test for the -48 Vdc Power Supply SM-F-935778
Step
Test setup instructions
Normal indications
If indication is abnormal
WARNING
Voltages dangerous to life are present on the -48 vdc
power supply (UUT) during this procedure; therefore
the ac line voltage should be turned off when bodily
contact must be made with connections on the UUT.
NOTE
Each test in this procedure is dependent upon the oth-
ers; therefore all tests should be performed in the order
that they are presented.