TM 5-4930-233-14
TM 4930-14/1
REEL CABINET ASSEMBLY
4-18. BATTERY BOX ASSEMBLY - SERVICE/REPLACE/REPAIR - (Cont.)
(5)
Remove nut (17), lockwasher (18), two flatwashers (21), screw (19) to disconnect ground lead (20). Reinstall
screw, lockwasher and nut.
(6)
Remove battery temperature sending unit by removing grommet from reel cabinet (para 4-17).
(7)
Remove nut (22) and starter lead (23).
4-41
|