Materials/Tools:
Hose Fittings (Male)
Hose, Hydraulic, High-Pressure
Tube Fittings (Female, Flareless)
Tape
Saw
Tool Kit
Vise
Procedural Steps:
(see para 8-15).
e. install the assembled hose on the vehicle.
f. Check that the hydraulic reservoir level is at least at the minimum operating level. if this level
is low, refer to para 8-13 and fill the reservoir as needed.
g. Operate ail hydraulic subsystems (except those that may still be damaged) to remove air from the
system. check carefully for fluid leaks. Tighten leaking fittings.
h. Check the hydraulic reservoir again to ensure a sufficient hydraulic fluid level. if this level is low,
refer to para 6-13 and fill the reservoir as needed.
When the mission is completed, as soon as practicable,
i. Record the BDAR action taken.
repair using standard maintenance procedures.
8-15
|