Page Title: Table 5-2. Pre-Test Inspection
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 32-5865-069-24&P
Pre-Test Inspection
Assembly/
Inspection
Normal
Procedure
method
indication
component
RSPU
Visual
a. Inspect exterior for dents,
a thru c must be
free of defects.
scratches, corrosion, dam-
aged or missing hardware.
b.
Inspect all controls, indi-
cators, and connections for
broken, loose or damaged
parts.
c. With top and bottom covers
removed, inspect all
cables, wiring, and
switches for burned con-
tacts and insulation, bro-
ken or loose connections
and other signs of damage.
A1 thru A10 and A12 contain parts sensitive to damage by Electro-
Use ESD precautionary procedures when
static Discharge (ESD).
touching, removing or inserting these assemblies.
Inspect for discolored,
CCA A1 - A1O Visual
a.
a thru c must be
loose, broken or burned
free of defects.
CCA A12
components and connections.
I
Inspect for cold solder
b.
joints, and excessive
c. Inspect board for cracks,
chips and breaks.
Visual
a. Inspect for dents,
IF Down
a and b must be
scratches, corrosion,
free of defects.
Converter
damaged, loose or missing
(A14)
hardware.
Inspect all cables and con-
b.
Converter
nectors for broken or loose
IF (A20)
connections and other signs
of damage.