TM 32-5811-024-14&P
Section IV. MAINTENANCE OF THE DIGITAL PROCESSOR TEST SET
6-6. General.
This section provides maintenance procedures that are the responsibility of intermediate support maintenance
personnel. The section includes inspection and cleaning of the digital processor test set.
6-7. Maintenance Procedures.
The following items should be performed along with intermediate support maintenance operations:
a. Inspection.
(1) Inspect all interior cables for kinks and strained, cut, frayed, or otherwise damaged insulation. Check cable
connectors for correct pin depths and make sure they are securely mounted to cables. The repair and
replacement of cables and connectors will be performed by depot level maintenance personnel only.
(2) Inspect exterior surfaces of the unit for dust, chipped paint, and corrosion.
If necessary, spot paint
surfaces as follows:
(a) Remove rust and corrosion from metal surfaces by lightly sanding them with no. 000 sandpaper.
(b) Brush two coats of light gray enamel, MIL-E-15090 class 2 type III color number 26307 IAW FED
standard 595, on bare metal to protect it from further corrosion.
(c) Refer to the applicable cleaning and refinishing practices specified in TB 43-0118.
b. Cleaning. Make sure exterior surfaces of the unit are clean. If necessary, clean exterior surfaces as follows:
(1) Remove dust and loose dirt with a clean, soft cloth.
(2) Remove dust and dirt from plugs and jacks with a brush.
6-5
|