![]() TM 32-5811-024-14&P
4-5. Daily and Weekly Preventive Maintenance.
The daily and weekly preventive maintenance checks and services are listed and described in tables 4-1 and 4-2.
Follow the steps in the order given. Defects discovered during operation will be noted for corrections to be made as soon
as operation has ceased. Stop operation immediately if a deficiency is noted that would damage the equipment. Record
all defects and the corrective action taken on the form specified in TM 38-750 (TAMMS).
Table 4-1. Daily Preventive Maintenance Checks and Services
Step
Item
Procedure
1
Cables
Inspect all exterior cables for kinks and strained
cut, frayed, or otherwise damaged insulation.
NOTE
Report any abnormal conditions to direct support
maintenance personnel.
2
Cleanliness
Make sure exterior surfaces of the unit are clean.
If necessary, clean exterior surfaces as follows:
a. Remove dust and loose dirt with a clean,
soft cloth.
b. Remove dust or dirt from plugs and jacks
with a brush.
WARNING
Adequate ventilation should be provided while
using trichlorotrifluoroethane. Prolonged
breathing of vapor should be avoided. The
solvent should not be used near heat or open
flame; the products of decomposition are toxic
and irritating. Since trichlorotrifluoroethane
dissolves natural oils, prolonged contact with
skin should be avoided. When necessary use
heavy duty rubber gloves that the solvent can-
not penetrate. If the solvent is taken internally,
consult a physician immediately.
c.
Remove grease, fungus, and ground-in dirt
using a cloth dampened (not wet) with
trichlorotrifluoroethane.
4-2
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |