Table 3-1. Digital Processor Test Set Controls, Indicators and Connectors - Continued
Control, indicator, or
connector
Function
CPU DISPLAY (cont)
PROGRAM ADDRESS
Six-digit indicators that display the unit-under-
(A1U4 thru A1U9)
test digital processor 16-bit program ROM address
in octal form.
INSTRUCTION
Eight-digit indicators that display the 24-bit
(A1U11 thru A1U18)
instruction output of the addressed unit-under-test
digital processor program ROM in octal format.
OVFL
LED indicator that displays the state of the ALU
(A1CR19)
overflow register of the unit under test:
LED on = overflow register set, LED off = overflow
register clear.
CARRY
LED indicator that displays the state of the ALU
(A1CR20)
carry register of the unit under test: LED on =
carry register set, LED off = carry register cleared.
RUN
LED indicator that displays the state of the
(AlCR1)
digital processor unit-under-test: LED on = digital
processor running, LED off = digital processor halted.
FAULT
LED indicator that lights when a unit-under-test
(A1CR2)
digital processor failure occurs.
COMMAND DISPLAY:
OCTAL DISPLAY
Six-digit indicators that display the unit-under-
test output word response to a SER. INT. CONTROL
test or COMM. PROC. TEST. This display is in octal
format.
DESIRED DELAY LINE
LED indicators that display the correct delay
CMD
line command generated by the df control. These
(A2CR1 thru A2CR12)
data are in binary form: LED on = 1, LED off = 0.
RESULTING DELAY
LED indicators that display the delay line preset
LINE CMD
(DLP) CMD generated by the df control. When the
(A2CR13 thru A2CR24)
unit-under-test is functioning normally, these data
match the DESIRED DELAY LINE CMD data. These data
are in binary form: LED on = 1, LED off = 0.
ANTENNA SWITCH CMD
LED indicators that display the antenna switching
(A2CR25 thru A2CR36)
command (ASC) generated by the df control test
command in binary form: LED on = 1, LED off = 0.
3-6