TM 32-5811-024-14&P
Table 3-1. Digital Processor Test Set Controls, Indicators, and Connectors
Control, indicator, or
connector
Function
Primary power:
POWER/POWER ON
Turns on power for equipment under test.
(illuminating
pushbutton)
DC and AC
Resets dc and ac breakers. If the ac breaker
(pushbuttons)
trips, the POWER ON pushbutton light goes out.
CPU CONTROL switches:
NORM ROM/DPTS ROM
NORM ROM - Allows unit-under-test program ROMs to
(S1)
control unit-under-test digital processor.
DPTS ROM - Allows digital processor test set
diagnostic ROMs to control unit-under-test digital
processor.
RUN
Allows unit-under-test digital processor to resume
(S2)
execution of instructions after it has been halted.
HALT
Stops unit-under-test digital processor.
(S3)
SINGLE STEP
Allows unit-under-test digital processor to execute
(S4)
its instructions one step at a time.
PRESET
Sets the unit-under-test program ROMs to an instruc-
(S5)
tion address preset on the ADDRESS switches (see
ADDRESS below).
BREAKPOINT
Presets the final instruction address (preset using
(S6)
ADDRESS switches) to be executed by the unit-under-
test digital processor before halting.
ADDRESS
The first switch on the left has two settings
(1 and 0), the remaining five switches have eight
settings (O thru 7). Select the ROM address
(RADO thru RAD15) or can be preset to the last
instruction executed; the address is in octal format.
SER. INT. CONTROL
switches:
CP STATUS/SER INT
CP STATUS - Routes the output of lamp driver CCA A8
(S7)
to the digital processor test set octal display.
3-2
|