![]() TM 32-5811-024-14&P
Table 2-3. Communication Processor Control-Indicator Test Cables
Cable
Function
W216, W217
See table 2-2.
W228
Transfers +5-V operating power and an output status word
to test the control-indicator display circuits.
W229
Connects +28 V dc to the control-indicator for panel
illumination power.
W237
Shorting plug used to test the control-indicator switches
and indicator lamps.
Table 2-4. Communication Processor Transceiver I/O Module Test Configuration Cables
Cable
Function
W216
See table 2-2.
W230
Coaxial cable to connect transceiver I/O module RCV CLK
output to the oscilloscope.
W231
Coaxial cable to connect transceiver I/O module RCV DATA
output to the oscilloscope.
W232
Coaxial cable to monitor XMIT CLK output of transceiver
I/O module via a T-connector.
W233
Coaxial cable to transfer XMIT CLK from a T-connector
to the test set.
W234
Coaxial cable to transfer XMIT CLK from the transceiver
I/O module to a T-connector.
W235
Coaxial cable to transfer XMIT data from the
test set to the transceiver I/O module.
W236
Three-way cable to transfer power and test relay commands
to the transceiver I/O module and for breaking out various
transceiver I/O signals for monitoring.
W241
Transfers data to the transceiver I/O module when used
with W235.
W242
Monitors tap for test set xmit data when used with W235
and W241.