TM 32-5811-024-14&P
Table 2-2. DF Test Configuration Cables
Cable
Function
W210
Connects 3- ac blower power to df display.
W211
Connects +28-V dc power to the df display.
W212
Shorting cable used in conjunction with digital processor
test set to test the df display's ability to transfer df
receiver commands.
W213
Connects serial interface test (same as flux gate compass
I/O) of digital processor test set to the serial interface
CCA of the df display.
W216
Connects 3- ac power to the digital processor test set.
W217
Connects +28-V dc power to the digital processor test set.
W218
Coaxial cable for monitoring the df control integrator ramp
waveform with an oscilloscope.
W238
Connects the integrator monitor of the df control to the
oscilloscope.
W239
Spare cable with no current application.
W240
Spare cable with no current application.
W243
Tests analog 0 when used in conjunction with CP3.
W244
Tests analog 0 when used in conjunction with W205 and CP3.
Moves from CP3 to oscilloscope.
CP3
T connector used to tap the oscilloscope to the analog
test signal.
W239P1
Connected to the digital processor test set JO1 connector
for a self-test of serial interface test CCA A6.
W240P1
Connected to the digital processor test set J13 connector
for a self-test of RF processor simulator CCA A5.