TM 32-5410-221-14&P
Table 5-2. Organizational Maintenance Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Step 2. Check socket for damage.
Replace socket if damaged. If there is no damage, replace bulb.
MECHANICAL
4. POWER CABLE REEL FAILS TO ROTATE PROPERLY.
Step 1. Check to see if reel is free from obstructions.
Remove obstructions.
Step 2. Check to see if reel is damaged.
Replace damaged reel.
Step 3. Check to see if reel is properly lubricated.
Lubricate reel bearings as required. See 5-5b.
Section VI. MAINTENANCE OF ELECTRICAL EQUIPMENT SHELTER S-281/G
5-8
GENERAL.
This
section
contains
c. Remove grease or oil with trichloroethane, item
organizational maintenance instructions as authorized
5, Appendix F. Wipe dry with clean, dry, lint-free cloth.
by the MAC. Instructions are for equipment cleaning,
d. Remove caked dirt with one-inch bristle brush
and removal and installation of equipment within the
soaked with trichloroethane. Wipe dry with clean, dry,
shelter.
lint-free cloth.
5-9
CLEANING.
5-10
SHELTER.
WARNING
a. Refer to TB 43-0124 for shelter maintenance.
Refer to TM 11-5410-206-14P for shelter repair parts.
The fumes of trichloroethane are
b. Refer to the applicable manual for air
toxic. Provide adequate ventilation
conditioner maintenance; models vary.
whenever it is used. DO NOT USE
c. Refer to the applicable manual listed in
NEAR
AN
OPEN
FLAME.
Trichloroethane is not flammable,
equipment.
but exposure of the fumes to an
d. Replace floor mat as follows:
open flame or hot metal forms highly
toxic phosgene gas.
WARNING
a. Remove dust and dirt from equipment with lint-
The shelter must be well ventilated
free cloth or vacuum cleaner.
when using cleaners and paints on
b. Remove dust and dirt from hard-to-reach areas
the shelter interior.
with one-inch bristle brush or vacuum cleaner.
5-9
|