Table 5-1. Organizational Preventive Maintenance Checks and Services - Continued
W - Weekly
Q - Quarterly
A - Annually
H - Hours
M - Monthly
S - Semiannually
B - Biennially
MI Miles
ITEM
INTERVAL
Item to be
Procedures
Equipment will be reported
NO
WM
QSAB
H MI
inspected
Not Ready (Red) if:
8
EXTERIOR
WARNING
POWER CABLES,
Disconnect power before per-
AND EARTH
forming step 8.
GROUND CON-
NECTION
Check for loose connections. Tighten as
necessary.
Inspect insulation, wires and terminals for
Damage renders shelter
damage such as cuts, abrasions, frays, breaks,
inoperative or causes safety
kinks and bends. Repair damage or replace
hazard.
parts as necessarily.
9
SHELTER
Inspect overall exterior for damage such as
Damage renders shelter
EXTERIOR
holes, open seam is, cracks, and punctures.
inoperative and is not
Repair damage.
repaired.
10
SHELTER DOOR
Check for fit and proper operation of hinges
Door is inoperative and
and Iatch. Repair or replace as necessary.
damage is not corrected.
11
SHELTER
Check for signs of seepage or leaks. Repair
Seepage or leaks render
INTERIOR
as necessary.
shelter inoperative, and
damage is not corrected.