2-7. PROTECTIVE ENTRANCE CONTROL MODULE (CONT).
LOCATION
ITEM
ACTION
REMOVAL
Panel
PURGE indicator light
1. Disassemble PECM (p. 2-33).
DS3
2. Remove insulation sleeving, and unsolder and
tag wires from PURGE indicator light DS3 (1).
3. Unscrew knurled lens (2) and nut (3).
4. Remove washer (4) and PURGE indicator light
DS3 (1).
5. Remove lamp (5) from PURGE indicator light
DS3 (1).
INSTALLATION
1. Install lamp (5) in PURGE indicator light
DS3 (1).
2. Insert PURGE indicator light DS3 (1) in panel
(6) and install washer (4) and nut (3), and
knurled lens (2).
3. Slide insulation sleeving (item 1, app C) over
wires.
4. Connect and solder wires to PURGE indicator
light DS3 (1). Refer to wiring diagram (p. 2-44).
5. Slide insulation sleeving over connections and
shrink.
6. Reassemble PECM (p. 2-33).