TM 3-1040-276-23
ORGANIZATIONAL PREVENTIVE MAINTENANCE CHECKS AND SERVICES SCHEDULE (CONT)
M - MONTHLY
S - SEMIANNUALLY
Interval
Item
Item
To Be
No.
M
Procedures
Inspected
S
3
Magneto air
a. Unwrap fog oil inlet and exhaust hoses.
pump
b. Disconnect ignition cable (1) from ignition magneto outlet (2).
assembly
Remove cap screw (3) with washer from bracket (4), clamp (5), and
c.
ignition magneto assembly (6) housing.
d. Remove cap screw (7), flat washer (8), nut (9), and Iockwasher (10),
from ignition magneto assembly (6) housing and clamp (5). Lift magneto
assembly (6) from clamp (5).
2-5