Click here to make tpub.com your Home Page

Page Title: CHAPTER 3 GENERAL SUPPORT MAINTENANCE INSTRUCTIONS
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

C 1, TM 3-1040-214-34
CHAPTER 3
GENERAL SUPPORT MAINTENANCE INSTRUCTIONS
half (5) from the pressure tank coupling plug assembly
3-1. Serviceability Tests
(14). Remove and retain the pressure tank.
(7) Vent the air under pressure in the pressure
General support maintenance personnel are responsible
tank by turning the handle counterclockwise.
for  recalling  all  dispersers  from  using  units  for
(8) Install the dust cap (13) on the plug assembly
hydrostatic-volumetric testing.
(14).
(9) If the plug assembly must be replaced, remove
a. Agent Tanks. Agent tanks will be subjected
the plug assembly (14) from the pressure tank valve
to a hydrostatic test at least once every 4 years. The date
(17).
the test is performed will be either stenciled on the agent
(10) If the check valve assembly (18) must be
tanks or stamped on aluminum tape.
Fasten the
replaced, remove the check valve assembly (18) from
aluminum tape around the diffusion pipe located
the pressure tank valve (17).
between the agent tanks.  Test procedures will be
performed in accordance with TM 3-1040-251-15.
b. Assembly.
b. Pressure Tank. The air pressure tank will be
(1) If the check valve assembly (18) has been
subjected to a hydrostatic-volumetric test at least once
removed, apply antiseize compound or tape on the
every 4 years. The date the test is performed will be
threads. Install and tighten the check valve assembly on
either stenciled on the pressure tank or stamped on
the pressure tank valve (17).
aluminum tape. Fasten the aluminum tape around the
(2) If the plug assembly (14) has been re- moved,
neck of the pressure tank.  Test procedures will be
apply antiseize compound or tape on the threads. Install
performed in accordance with TM 3-1040-251-15.
and tighten the plug assembly on the pressure tank valve
(17).
3-2.
Pressure  Tank
Check
Valve
and
Plug
Assemblies
c. Servicing.
General support maintenance personnel are authorized
(1) Charge and test the pressure tank for leaks
to replace the pressure tank check valve assembly and
according to instructions in TM 3-1040- 221-12.
the plug assembly.
(2) Use approved compressors listed in TM 3-
1040-214-12.
a. Removal.
(3) Apply soapy water around the check valve
assembly and the plug assembly and check for possible
1) Close the pressure tank check valve by turning
leaks.
the handle (B, fig. 2-1) clockwise.
(4) If leaks occur, reinspect all connections.
(2) Open the shutoff valve by turning the handle
Tighten or replace the assembly. Perform step (1) above
(fig. 1-1) counterclockwise.
after tightening or replacing the assembly.
(3) Place the agent tanks in a horizontal position
with the pressure tank on top.
d. Installation.
(4) Loosen the wingnut, and disconnect the hinged
clamp that holds the pressure tank in place.
(1) Place the agent tanks in a horizontal position,
(5) Remove and retain the wingnut (11, fig. 2-5)
with the carrier pack on the bottom.
and eyelet (7).
(2) Check to see that the valve handle (step B, fig.
2-1) is closed (counterclockwise).
CAUTION
(3) Remove the cap (13, fig. 2-5), from the plug
assembly (14).
Exercise care when disconnecting
(4) Place the pressure tank on the agent tanks.
the quick-disconnect coupling half
from the pressure tank coupling plug
to prevent possible damage to the
tube.
(6) Disconnect the quick-disconnect coupling
3-1

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business