(5) Perform test in c below.
(2) Check to see that the coupling cap (A, fig 2-1)
is installed.
(6) Connect the carrier pack (8, fig 2-8)
to
the
(3) Open the pressure tank valve by turning the
frame with the cords (9) removed in a(2) above.
(7) Connect the straps (removed in a(5) above) to
valve handle (B, fig 2-1) counterclockwise.
(4) Apply soapy water around all the connections
the frame.
and fittings and check for leaks.
(5) Retighten all fittings if leaks are found and
c
Test.
perform (4) above.
(1) Close the shutoff valve (2, fig 2-6) by turning
the handle clockwise.
Section IV. PAINTING
2-7. General
2-8. Paints to be Used
a.
Primer. Prime all worn and scratched
Direct support maintenance personnel are authorized to
repaint the disperser.
surfaces with one coat of appropriate primer.
b. Enamel. Repaint all previously painted
surfaces with green lusterless enamel.