C 1, TM 3-1040-214-12
1
Agent tank
9
Adapter
17
Inlet adapter
2
Hose assembly
10
Washer
18
Pressure regulator
3
Quick-disconnect coupling half
11
Safety valve
19
Needle valve-2
4
Pipe and cap assembly
12
Safety head
20
Needle valve-1
5
Diffusion tube assembly
13
Pressure tank
21
Vent tube
6
Preformed packing
14
Coupling plug
22
Shutoff valve
7
Screw
15
Quick-disconnect coupling plug
23
Setscrew
8
Nut
16
Tube assembly
24
Shutoff valve handle
Figure 4-5-Continued
CAUTION
(5) Close the hinged tank clamp (Fig.  1-4)
Exercise care when disconnecting
around the pressure tank and fasten the attached
the pressure tank coupling plug from
wingnut.
pressure regulator quick-disconnect
(6) Fasten the valve shaft to the boss on the
coupling half to prevent damage to
agent tank with the clamp and wingnut.
the tube.
(5) Disconnect the quick-disconnect coupling half
4-11.  Approved
Air
Compressors
and Service
(15, Fig. 4-5) from the coupling plug (14).
Units
(6) Remove and retain the pressure tank and valve
assembly.
a. Approved Air Compressors.  Compressors that
have been approved for charging pressure tanks of the
(7) Install cap on the pressure tank coupling plug (4).
M3 dispersers are listed below:
c. Installation.
(1) M1A1 7 cfm power-driven reciprocating
(1) Remove the cap (Fig.
1-5) from the
compressor (TM 3-1040-203-12).
coupling plug.
(2) AN-M4 3 1/2 cfm flamethrower power-
(2) Place the tank group in a horizontal
driven reciprocating compressor (TM 3-1040210-12).
position with the quick-disconnect coupling half facing up
(3) AN-M4B 3 1/2 cfm flamethrower power-
driven reciprocating compressor (TM 3-1040224-12).
(3) Align and connect the pressure tank
(4) AN-M4C 3 1/2 cfm flamethrower power-
coupling plug (14, Fig.  4-5) to the pressure regulator
driven reciprocating compressor (TM 31040-244-12).
quick-disconnect coupling half (15).
(5) AN-M4D 3 1/2 cfm flamethrower po wer-
(4) Test to see that the coupling plug is
driven reciprocating compressor (TM 31040-263-12).
engaged and locked in the quick-disconnect coupling
half. The knurled ring on the quick-disconnect coupling
b. Approved Service Unit.  The service unit that
half should not slide freely when properly connected.
has been approved for charging pressure tanks for the
M3 Disperser is the M4A2 service unit flamethrower
truck-mounted (TM 3-1040-219-12).
Section III. DECONTAMINATING AND CLEANING
4-12. General
NOTE
Dispersers that have been used on a mission are
Use soap and water to clean the
partially  cleaned  by  the  operator  (para  2-10).
equipment when talc is used.
Organizational maintenance personnel will disassemble
and completely decontaminate the disperser when it is
4-13. Decontaminating Solution
returned
to
organizational
maintenance.
Decontaminating operations on the gun group, hose
NOTE
group, and tank group are outlined below.  TM 3-220
Decontaminating solution is used to
contains additional decontamination procedures.
decontaminate
equipment
that
contains agent.