TM 11-6625-667-45/NAVAIR 16-30APM123-2/TO 33A1-367-22
Control
Position
result should be 1,090 1 MHz. If it is not, adjust
FUNCTION . . . . . . . . . . . . . . SYSTEM
the AN/URM-64 until it is.
MODE . . . . . . . . . . . . . . . . . . 1
g. Connect the output of the MD-796 as shown
CODE(A, B, CA D) . . . . . . . . . . 0000
in figure 7-1.
ISLS . . . . . . . . . . . . . . . . . . . . OFF
h. Set the AN/USM-281 controls as follows
PUSH TO TEST . . . . . . . . . . . Released
DIR/RAD . . . . . . . . . . . . . . . . RAD
POWER: ON
Sweep Display Switch: Delayed
c. Set and adjust AN/UPM-137A rf signal gen-
Delayed TIME/DIV; 5
erator as indicated below:
Man TIME/DIV; 10sec
Control
Position
Sweep MODE AUTO
-6 dbm
OUTPUT ATTEN 0-100 dbm
MAIN SLOPE:
TRANSMITTER-XMTR
DELAYED SLOPE: -
FREE . . . . . . . . . . . . . . . . . XTAL
DIV DELAY: .02
TRANSMITTER-CW
Main Trigger Source Switch: EXT.
SOURCE . . . . . . . . . . . . . . . EXT 1090 MHz
DISPLAY: A
e. Set AN/UPM-137A Interrogator Signal
A VOLT/DIV: 5
A POLARITY: + UP
Simulator TRANSMITTER-XMTR FREQ to XTAL.
A Input Coupling Switch: AC
e. Set and adjust AN/UPM-137A SIS generator
i. Connect the rest of the equipment as shown in
as indicated below;
Control
Position
SIF 1 CODER-FUNCTION
j. PresS and lock and test set PRESS TO TEST
SEA. . . . . . . . . . . . . . . . . . . N
switch; set the MODE switch to 1, CODE switch to
SIF 1 CODER-CODE ... ... . 0000
7777 and FUNCTION switch to SYSTEM.
SIF 1 CODER-WIDTH ADJ . . Approx. center
k. Set the controls of the AN/UPM-98 SIF
SIF 1 CODER-SUBST PULSE
CODER unit as follows:
SEL. . . . . . . . . . . . . . . . . . . OFF
CODE: 7777
MIXED VIDEO-MIXED VID
FUNCTION: N
SEL.. . . . . . . . . . . . . . . . . . SIP 1
SUB PULSE SELECT: Cl
PRF-RANGE MULT . . . . . . . EXT.
SUB PULSE POSITON: O
TRIGGERS-DELAY TRIG
LEVEL: HI
(SEC)-DLY RANGE
PULSE WIDTH: 0.45
MuLT . . . . . . . . . . . . . . . . . X4
TRIGGERS-DELAY TRIG
/. Connect oscilloscope CHANNEL A to A8TP2
(SEC)-MULT1-11. . . . . . . 6.0
and observe the detected video. Adjust the
7-4. Receiver
Frequency
and
AN/UPM-98 AMPLITUDE control for a convenient
amplitude of pulse.
NOTE
When the AN/URM-64 frequency is
point A4TP5 and CHANNEL A to A8TP6.
changed, the POWER SET meter of the
n. Set the AN/UPM-98 XTAL MARK SYNC con-
AN/URM-64 should be reset to 0.
trols as indicated below:
Connect the equipment as shown in figure 7-1. Set
Control
Position
and adjust the controls as described in paragraph
SYNC SELECT . . . . . . . . . . . . -EXT.
SUP . . . . . . . . . . . . . . . . . . . . MAXIMUM CCW
TRIGGER DELAY . . . . . . . . . To the point where the first
a. Decrease the AN/URM-64 rf output with the
pulse at oscilloscope CHAN-
ATTENUATOR control until the teat set barely in-
NEL A is delayad 5 micro-
dicates ACCEPT and then increase the
seconds from the leading
AN/URM-64 rf output 3 dB.
edge of the second puke at
CHANNEL B.
b. Use the AN/URM-64 SIGNAL FREQUENCY
control to decrease the frequency until the test set
7-3.2. Initial Test Procedures Using
--
barely indicates ACCEPT. Use the AN/USM-207
AN/UPM-137A
a n d the CM-77A/USM to determine the
a. Use AN/UPM-137A to make connections
AN/URM-64 output frequency. Note this fre-
shown in figure 7-1.l.
quency.
b. Set and adjust test set controls as indicated be-
c. Reconnect the AN/URM-64 to the MD-796.
low:
Increase the AN/URM-64 frequency until the test
7-2 Change 4
|