TM 11-6425-647-45/NAVAIR 16-30APM123-2/TO
33A1-3-367-22
CHAPTER
7
DEPOT OVERHAUL STANDARDS
NOTE
See Chapter 7.1 For procedures Using AN/TPM-25A.
7-1. Applicability of Depot Overhaul
Radar Test Set AN/UPM-137A. Paragraph 7-3.1
and figure 7-1 describe the initial setup and adjust-
Standards
ments for the tests without the AN/UPM-98A and
The tests outlined in this chapter are designed to
measure the performance capability of a repaired
tial setup and adjustment for the tests using the
equipment. Equipment that is to be returned to
AN/UPM-137A. For all of the test procedures,
stock should meet the standards given in these
refer to figure 3-6 for test point location and figure
tests.
7-2. Applicable References
7-3.1. Initial Test Procedures Using
AN/UPM-98A or AN/UPM-98B
a. Repair Standards. Applicable procedures of
the depots performing these tests and the general
a. Use the equipment in (1) through (6) below to
standards for repaired electronic equipment given
make the connections shown in figure 7-1. Connect
in TB SIG 355-1, TB SIG 355-2, and TB SIG 355-3
the AN/URM-64 to the CM-77/USM.
form a part of the requirements for testing this
(1) Oscilloscope AN/USM-281A.
equipment.
(2) Frequency Meter AN/USM-207.
b. Technical Publications. The technical publica-
(3) Comparator, Frequency CM-77A/USM.
tions applicable to the equipments to be tested are
(4) Modulator MD-796.
indicated below:
(5) Generator, Signal AN/URM-64A.
Equipment and subject
Publication
(6) Test Set, Radar AN/UPM-98.
Operator's and Organizational and
TM 11-6625-667-12
NOTE
Maintenance Manual Teat Set,
Either the AN/UPM-98A or the
Transponder AN/APM-123(V)1,
AN/UPM-98B may be used for all proce-
AN/APM-123(V)2, and
AN/APM-123(V)3
dures.
(NSN 6625-00-948-0071).
on t h e A N / U R M - 6 4 , A N /
b. Turn
General Support and Depot
TM 11-6625-667-45
USM-207, and CM-77A/USM. Allow l-hour warm-
Maintenance Manual: Teat Set,
up period
Transponder AN/APM-123(V)l,
c. Set the AN/USM-207 controls as indicated be-
AN/APM-123(V)2, and
AN/APM-123(V)3
low:
(NSN 6625-00-948-0071).
DIRECT/HETERODYNE switch: HETERODYNE
VOLTAGE switch: 10V
c. Modification Work Orderss. Perform all modifi-
FREQ TUNING-MC: 200
tation work orders applicable to this equipment be-
POWER: TRACK
fore making the tests specified. DA Pam 310-4 lists
FUNCTION: FREQ.
all available MWO's.
SENSITIVITY: PLUG IN
d. Set the AN/URM-64A FUNCTION control to
7-3. General Requirements
CW, ATTENUATOR control to -9 dBm, and SIG-
The majority of the depot overhaul standards tests
NAL FREQUENCY control to 1,090 mc.
shall be performed using the test setups shown in
e. Turn on all test equipment that was not turned
on previously.
adjustments described in paragraphs 7-3.1 or 7-3.2
and modify these as required for the individual
MEGACYCLES dial for zero beat indication. Ob-
tests. Two test procedures are provided for those
serve the indication on the AN/USM-207. Add 200
tests that use test equipment that is replaced by
to the number and multiply the result by five. The
Change 5 7-1
|