TM 11-6625-667-45/NAVAIR 16-30APM123-2/TO 33A1-3-367-22
Position
Control
set just barely indicates ACCEPT. Using the
VERTICAL-CHAN B-AC/DC. DC
AN/USM-207 and CM-77A/USM, measure and
VERTICAL-CHAN B-75
note the frequency.
IN/OUT . . . . . . .. ... ..... 5
d. Subtract the frequency obtained in b above
VERTICAL-CHAN
from that obtained in c above. The results should be
B-VOLT/DIV.. . . . . . . . . . . OFF
6.5  1 MHz.
CALIBRATORS-XTAL
MARK (SEC) . . . . . . . . . . . OFF
e. Add the two frequency values determined in b
HORIZONTAL-SWEE
and c above and divide by two. The results should be
DELAY (SEC)-DLY
1,090 .5 MHz.
RANGE MULT . . . . . . . . . .  X400
f. Set and adjust AN/UPM-137A oscilloscope as
HORIZONTAL-SWEEP
indicated below:
DELAY (SEC)-MULT
1-11 . . . . . . . . . . . . . . . . . .  As required for proper dis-
Position
Control
play.
EXT DC-
HORIZONTAL-SYNC . . . . . .
g. Turn on AN/UPM-137A and test set and allow
DISPLAY-CHAN A/ALT/
CHANT . . . . . . . . . . . . . . .  ALT
5-minute warmup.
VERTICAL-CHAN A-AC/DC.  DC
h. Press test set PUSH TO TEST and turn to
VERTICAL-CHAN A-75
LOCK position. Test set ACCEPT indicator should
IN/OUT.. . . . ... . . . . . . . .  OUT
light.
VERTICAL-CHAN
A-VOLT/DIV . . . . . . . . . . . .  5
Change 4
7-3

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business