5.2-7. Video Enable Delay and Period Test
a. Test equipment required
(1) Generator, Pulse AN/UPM-15A
(2) Oscilloscope, AN/USM-281A.
(3) Test Set, Radar AN/TPM-25A.
b. Test Connections and Conditions. Performs the system timing setup as described in the chart in
paragraph 5.2-4 c step ( 1). Then connect the equipment as shown in figure 5.2-5, video enable delay and
period test.
c. Procedure
Control settings
Test procedure
Equipment under test
Performance standard
Step
Test equipment
MODE: 2
AN/TPM-25A
a None.
1
REPLIES panel:
CODE (A, B, C, D): 0000
to A10TP5.
FUNCTION: SYSTEM
MODULATION SEL: SIF
b. Observe video enable delay
b. The video enable delay 1.8
POWER: ON
PULSE WIDTH: 0.45
pulse on A INPUT. Measure
PRESS-TO-TEST LOCK
SIF REPLY CODE: 0000
pulse width.
SUB PULSE SEL: OFF
RANGE DELAY SEL SEC):
0001
GATING PASS: 00
GATING INHIBIT: 00
M4 JAMMING: 0
TRIG SEL INT/DCD/EXT
EXT
SIG GEN FUNCTION:
FIXED FREQ
SUM ATTEN: 0 DB
POWER: ON
AN/USM-281A
POWER. ON
Sweep display switch MAIN
MAIN TIME/DIV: 2
INT/AUTO/EXT/EXT10
EXT
MAIN SLOPE + : +
DIV DELAY: 852
DISPLAY: A
A and B VOLTS/DIV: 5
A and B POLARITY: + UP
A and B AC/GND/DC: DC
a None.
2
AN/USM-281A
DISPLAY: ALT
to A9TP4.
|