5.2-4. Transmitter Power Test
a. Test Equipment Required
b. Test Connections and Conditions.
(1) Connect the equipment as indicated in c below.
(2) Connect test point A4TP5 to ground (module A4 at the rear of test set.
c. Procedure.
Control settings
Equipment under test
I Performance standard
Test procedure
Test equipment
Step
INone.
MODE: 1.
None
N/A
1
Code Any.
FUNCTION: SYSTEM
POWER ON.
ISLS: OFF
CAUTION
The test equipment settings
Controls remain as in step 1.
TS 779A/U
2
must be performed before the
BOLO BIAS CURRENT OFF.
MX-2144A/U, is connected to
BOLO
avoid equipment damage.
RES:200.
a Connect the MX-2144A/U to the a. None.
B O L O TEMP COEF: NEG.
TS 779A/U.
RANGE:
b. None.
b. Adjust the TS 779A/U as
0 DBM.
follows: (1) Set the BOLO BIAS
CURRENT switch to 10-16 MA. I
(2) Set the LINE POWER
switch to ON, and permit a
15-minute warmup. -
(3) Adjust the ZER0 SET
COARSE AND FINE
controls to zero meter.
c. Connect the equipment as shown c. None.
in figure 5-2. Make sure that test
point A4TP5 is grounded.
d. Connect the MX-2144A/U to d. -61 dbm.
the test set PROBE jack. Ob
serve the power indication.
e. Disconnect the ground from e. None.
test point A4TP5, and connect
test point A4TP4 to ground.
Disconnect the MX-2144A/U.
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |