Control settings
I
Step I
Test equipment
Equipment under test
Performance Standard
Test Procedure
2
f. Set the RANGE switch to 10
f. Meter deflects slightly to
(Cont)
right (approximately 21
DBM and readjust zero set
dbm).
coarse and fine controls to zero
meter.
Reconnect
the
MX-2144A/U to
the
AN/APM-123 PROBE con
nector. Observe the power meter
reading.
g. Remove the jumper from A4TP4
to ground.
5.2-5. Transmitter Output Pulse Test
a. Test Equipment Required.
(1) Oscilloscope, AN/USM-28A.
(2) Radar Test Set, AN/TPM-25A.
b. Test connections and conditions. Perform the system timing setup as described in the chart in
characteristics test setup.
c. Procedure
Control settings
Test Procedure
Step I Test equipment
Performance Standard
Equipment under test
---- --
--.
1
AN/TPM-25A
a. None.
POWER ON
FUNCTION: SYSTEM
MEASUREMENT FUNCTION
test set. Permit a few minutes
ISLS: ON.
SEL PWR
warmup.
POWER: ON.
b. A d j u s t t h e o s c i l l o s c o p e
b. (See(1) through (3) below.
REPLIES MODULATION SEL
PRESS TO TEST: LOCK
MAIN TRIGGER LEVEL,
SIF
INTENSITY, and FOCUS for a
REPLIES SUB PULSE SEL:
MODE: 1.
clear view of the pulses and the. 1
OFF
s markers displayed on
PRT SEL ( SEC) 4000
oscilloscope.
TRIG SEL INT DCD/EXT INT
(1) Pulse widths 0.8 0.1
(1) Measure pulse widths at 50%
SIG GEN FUNCTION: FIXED
points.
FREQ
I
|