Control settings
Normal Indication
Procedure
Equipment under test
Test equipment
Step
(2) Delay between P1 and
(2) Measure d e l a y b e
AN/USM-2181A
P2 shall be 2 0.2
tween P1 and P2 at 50%
POWER ON
points.
Sweep display
(3) Mode spacing
(3) Measure spacing between P1
switch DELAYED
3 0.2 s.
and P9 at 50% points.
DELAYED TIME/DIV: 1 SEC
c. See(1) through (4) below.
c. Set the test MODE switch at
MAIN TIME/DIV: .1 MSEC
each of the positions, in (1)
INT AUTO/EXT/EXTl0: AUTO
through (4) below and repeat the
EXTl0/EXT/INT/LINE: EXT
procedure in b above to measure
MAIN +SLOPE +:+
delays between P1 and P3.
DIV DELAY: 02
(1) Mode 2 spacing 5 0.2
(1) 2 . . . . . . . . . . . . . . . . . . . . . . .
DISPLAY: A
s.
A and B VOLT/DIV: 5
(2); Mode 31A spacing:
(2) 3/A . . . . . . . . . . . . . . . . . . . . .
A and B POLARITY: + UP
80.2
A and B AC/GND/DC: DC
Mode C spacing 21
(3) C . . . . . . . . . . . . . . . . . . . . . . .
0.2 s.
(4) Mode TEST spacing
(4) TEST . . . . . . . . . . . . . . . . . . .
6.5 0.2 s.
|