CONNECTOR UG-1870A/U REPLACEMENT (CONT)
34. Install spring (1) onto one coaxial line, and into rear insert (2) counterbore.
NOTE
Be careful to install correct coaxial body assembly (3) on coaxial cable.
35. Screw corresponding coaxial body assembly (3) over center contact and onto coaxial braid
clamp (4).
36. Repeat steps 34 and 35 on remaining coaxial line.
37. Using 3/8-inch open-end wrench, hold coaxial body (5) while tightening braid clamp nut (6)
securely with 5/16-inch open-end wrench.
38. Repeat this step for other coaxial body
39. Using a torque wrench, torque each clamp nut (6) to 30-35 inch-pounds.
3-14