CONNECTOR UG-1870A/U REPLACEMENT (CONT)
NOTE
Be sure angled portion of large ring (7) faces front end of connector shell assembly (8)
when installing.
40. Install large ring (7) of cap shell assembly on connector shell assembly (8).
41. Insert nyloc screws (9) in rear insert (10).
NOTE
When installing rear insert (10), make sure male body assembly is inserted in
connector shell (8) insert hole that has larger opening in face seal. Make sure also that
both coaxial contacts are through face seal, and rear insert (10) butts against
connector shell (8) insert.
42. Install rear insert (10) into rear of connector shell assembly (8).
43. Using a 3/32-inch internal socket wrench, tighten two nyloc screws (9) until they
are seated.
44. Using a torque wrench, torque each nyloc screw (9) to 3-5 inch-pounds.