TM 11-5895-833-12/NAVELEX 0967-LP-550-1010/TO 31R5-2TSC54-91
SECTIN II. MAINTENANCE ALLOCATION CHART
(1)
(2)
(3)
(4)
(5)
GROUP
FUNCTIONAL GROUP
MAINTENANCE FUNCTIONS
TOLS AND
REMARKS
NUMBER
COMPONENT ASSEMBLY
EQUIPMENT
D
32
Cleaning
0.3
D
3, 4, 5, 8, 9, 12,
Test to determine
3.0
31, 32, 33, 38,
54, 69, 84, 89
D
Depot disposition
3.5
0238
RF Input Stripline Assembly
F
See note. Tested at next
(1A2DC1) (Coupler, Directional)
0.6
higher assembly.
F
Visual Inspection
0.1
D
32
Cleaning
0.3
D
3, 4, 5, 12, 18,
Test to determine status.
0.6
19, 32, 33, 37,
50, 51, 61., 73,
89, 117
D
Depot disposition
18.0
0240
Wiring Harness, Interconnection
F
F
30, 32, 33
(1A2W29)
0.1
0.5
0242
Wiring Harness, Ac Prime Power
F
F
30, 32, 33
(1A2W30)
0.1
0.5
0244
Amplitude Step Attenuator (1A2AT5)
F
See note. Tested at next
(Attenuator Assembly)
0.6
higher assembly.
F
Visual Inspection
0.1
D
32
Cleaning
0.1
D
3, 4, 14, 32, 33,
Test to determine status.
1.5
54, 61, 71, 89
C-8
|