TM 11-5895-833-12/NAVELEX 0967-LP-550-1010/TO 31R5-2TSC54-91
SECTIN II. MAINTENANCE ALLOCATION CHART
(1)
(2)
(3)
(4)
(5)
GROUP
FUNCTIONAL GROUP
MAINTENANCE FUNCTIONS
TOLS AND
REMARKS
NUMBER
COMPONENT ASSEMBLY
EQUIPMENT
0230
RF Conversion Stripline Assembly
F
See note. Tested at next
(1A2CR1) (Mixer, Stage, Frequency)
0.6
higher assembly.
F
Visual Inspection
0.3
D
32
Cleaning
0.3
D
3, 4, 5, 6, 12, 17,
Test to determine status
6.0
18, 19, 27, 30,
32, 33, 37, 40,
41, 50, 51, 55,
57, 59, 61, 65,
69, 71, 73, 78,
89, 114, 117, 118
D
Depot disposition
8.0
0234
IF Conversion Stripline Assembly
F
See note. Tested at next
(1A2CR2) (Mixer, Stage, Frequency)
0.7
higher assembly.
F
0.1
D
32
Cleaning
0.2
D
3, 4, 5, 8, 10, 14
Test to determine status.
5.0
17, 32, 33, 41,
50 thru 55,
59, 61, 67, 69,
71, 72, 78, 89,
114, 116
D
Depot disposition
9.0
0236
Phase Equalizer (1A2EQ1)
F
See note. Tested at next
(Filter, Phase Compensating)
0.7
higher assembly.
F
Visual Inspection
0.2
C-7
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |