TM 11-5895-833-12/NAVELEX 0967-LP-550-1010/TO 31R5-2TSC54-91
SECTIN II. MAINTENANCE ALLOCATION CHART
(1)
(2)
(3)
(4)
(5)
GROUP
FUNCTIONAL GROUP
MAINTENANCE FUNCTIONS
TOLS AND
REMARKS
NUMBER
COMPONENT ASSEMBLY
EQUIPMENT
0120
Microwave Signal Divider (1A11)
0
Monthly Inspection
(Divider, Microwave Signal)
0.1
0
32
Cleaning
0.3
F
2,3,4,32,33,36
See note. Test to determine
1.3
status
D
32 thru 35
Replacement to be performed
2.0
by depot. Depot disposition.
0130
Cabinet Subassembly, Down
F
F
Repair defective cables and
0.5
1.5
harness.
013001
Wiring Harness, Ac Power (1W1)
F
F
30, 32, 33
0.1
0.5
13002
Wiring Harness, Radio Frequency
F
F
30, 32,33
(1W2)
02
CONVERTER, FREQUENCY,
0
Daily and monthly inspections
ELECTRONIC CV-3085/MSC-46(V)
0.5
(1A2, 1A3, 1A4)
AND
CONVERTER, FREQUENCY,
0
32
Cleaning
ELECTRONIC CV-3085A/MSC-46(V)
0.2
F
2,3,4,5,7,8,9,10,11,14, See note. Test to determine
0.3
15,16,17,18,19,21,22, status.
23,30,31,32,33,34,35,
36,37,38,39,40,43,46,
59,64,65,66,68,74,79,
91,97,103,108,110,
114,117,119
F
32,33
See note. Adjustment after
0.2
module replacement.
C-4
|